Rated operating temperature: 1650℃
Long-term operating temperature: 1600℃
Temperature control accuracy: ±1℃
Uniformity of temperature field inside the furnace: ±3℃ (depending on the size of the heating chamber)
Temperature measurement element and temperature measurement range:
Rhodium-rhodium-platinum B thermocouple, temperature measurement range 0~1350℃
The number of programming curve segments: 50 segments for Group One, 20 segments for Group Two, and 8 segments for Group three
Heating rate: Adjustable from 1℃/h to 20℃/min
The opening method of the furnace door: Top door opening
Heating element: Silicon-molybdenum rods are used as heating elements.
Distribution of heating elements: Evenly distributed around the furnace chamber
Protection: It is designed with dual-loop control and dual-loop protection, featuring overshoot,
overshoot, undershoot, phase couple, phase loss, overvoltage, overcurrent, over-temperature, current feedback, soft start and other protections
Display parameters: temperature, temperature segment number, segment time, remaining time, output power percentage, voltage, current, etc
Touchscreen control: 7-inch true-color touchscreen
Vacuum value (vacuum gauge) : -0.1MPa
Air inlet: 1
Air outlet: 1
Vacuum pump: Mechanical rotary vane pump
Water cooling: Bring your own water source
Cooling parts: Furnace door, furnace mouth
Permeable atmospheres: hydrogen, nitrogen, argon, carbon monoxide, oxygen, etc
Refractory materials: High-purity alumina fiber board
Warranty scope and period: The electric furnace is covered by a one-year free warranty.
The heating element is not covered by the warranty (free replacement for natural damage within three months).